Email: [email protected] Tel: +86 18626018485


Breast-treatment apparatus ZJ-7000B Model (Supreme Edition)

ZJ-7000B Model (Supreme Edition)Seven selectable treatment modes (Dense Wave, Needle Wave, Sparse Wave, Undulating Wave, Intermittent Wave, Undulating Intermittent Wave, Variable Frequency Wave).Input Power: ≤40VA.Adjustable levels of infrared radiation intensity: 1 to 18 levels, with intensity inc

          
Product Description:

ZJ-7000B Model (Supreme Edition)

  1. Seven selectable treatment modes (Dense Wave, Acupuncture Wave, Sparse Wave, Undulating Wave, Intermittent Wave, Undulating Intermittent Wave, Variable Frequency Wave).

  2. Input power: ≤40VA.

  3. Adjustable levels of infrared radiation intensity range from 1 to 18 levels, with intensity increasing sequentially at level 18, and infrared light output power ≤0.1W.

  4. Effective spectral wavelength range of the probe: 0.8~3um.

  5. Timing range: The working time of the therapeutic device should be continuously adjustable within the range of 0 to 99 minutes, with an accuracy error of ±1 minute. After reaching the set time, there will be an audible indication, and the working indicator light will go out.

  6. Infrared radiation temperature: When the therapeutic device is in working state, with the infrared radiation intensity set to the strongest 18 levels, the surface temperature of the probe should be ≤41 degrees within 30 minutes.

  7. Operation error alarm: In working state, if the operation steps specified in the product manual are not followed, an audible alarm will be triggered.

  8. Infrared radiation alarm: In working state, if the set infrared radiation intensity is 18 levels, when the working accumulates to 5 minutes, 15 minutes, and 30 minutes, the infrared radiation intensity will automatically decrease to 18 levels, 17 levels, and 16 levels respectively, accompanied by an audible alarm.

  9. Equipped with a 10.4-inch high-brightness professional touch screen for more intuitive operation.

  10. Dual-channel output, can treat two patients simultaneously.

  11. Three different probes are available for selection.

  12. When the electric pulse is maximally output, the energy of a single pulse is ≤300mJ.

  13. Maximum output amplitude effective value, frequency ≤400Hz, frequency ≤1000Hz, and >1000Hz, the limit of electrode voltage or current is not greater than 20V (50mA), 40V (60mA), 40V (80mA) respectively.

  14. Four treatment modes: Infrared Heat Radiation, Electric Pulse Stimulation, Drug Ion Import, and Magnetotherapy.

  15. Continuous working time: More than 8 hours.

  16. Output intensity adjustment range: 0–99 levels.

  17. Voltage output peak-peak value Vpp: 0~38V.

  18. Trolley design for easy mobility.


Get the latest price? We'll respond as soon as possible(within 12 hours)
Leave a message

Facebook

Twitter

LinkedIn

Youtube

instagram

+86 18626018485

Skype

WhatsAPP

[email protected]

8704401

Top