Home >> Products >> Ozone therapy
ZJ-9000C Supreme Ozone Therapy Device ParametersI. Product Introduction:The ZJ-9000C Supreme LCD Touch Medical Ozone Therapy Device is an advanced technology product incorporating seven functions: ozone, atomization, flushing, automatic heating, automatic water supply, ozone recovery, and LCD touc
ZJ-9000C Supreme Ozone Therapy Device Parameters
I. Product Introduction: The ZJ-9000C Supreme LCD Touch Medical Ozone Therapy Device is an advanced technology product incorporating seven functions: ozone, atomization, flushing, automatic heating, automatic water supply, ozone recovery, and LCD touch. It utilizes the technology of reactive oxygen ions to treat diseases of the female reproductive system. Ozone possesses highly efficient, rapid, and broad-spectrum bactericidal characteristics. It diffuses ozone to the affected area, exerting a powerful killing effect on pathogenic microorganisms such as bacterial reproductive bodies, bacterial spores, viruses, fungi, etc. Thus, it can treat various gynecological diseases caused by pathogenic microorganisms. The active ingredients can promote the growth of epithelial cells and wound healing, achieving a thorough cure for diseases like cervicitis, vaginitis, and pelvic inflammatory diseases. The treatment ensures full and comprehensive contact with the lesion, leaving no dead angles and providing a thorough cure. The treatment is non-invasive, bloodless, and painless, leaving no scars, and in the case of treating cervicitis, other concomitant reproductive tract inflammations can be cured simultaneously. Additionally, ozone has a self-disinfection function for the device, making it easy to use with excellent clinical results.
II. Technical Parameters:
Ozone concentration: ≥80mg/m3, not exceeding 1000mg/m3 Ozone flow rate: 1.5~6L/min Adjustable heating temperature range: 30℃-35℃, error ±10% Water temperature heating time: Heating to 35℃, time ≤30min Liquid storage tank volume: >4L Timing function: Adjustable timing in the range of 00~60min, timing error not exceeding ±2% Flexible operation of each function key, correct display Continuous operation time: ≥8 hours Automatic completion of liquid application within 3 minutes, molded appearance, international streamlined design.
LCD touch, leading technology, unique in the country, with national patents.
Fully automatic ozone recovery technology, national patent, fundamentally improving the treatment environment Equipped with an over-temperature protector, the machine has sound alarms. Equipped with forced drainage function Ozone gas leakage ≤0.16mg/m³, normal working noise of the instrument ≤60dB(A)
III. Product Features and Introduction: Ozone (O3) for the treatment of gynecological diseases, sexually transmitted diseases, and skin diseases. High-concentration ozone water is directly flushed into the vagina, effectively treating conditions such as candida vaginitis. High-concentration ozone water has a killing effect on Escherichia coli and Staphylococcus aureus. During vaginal flushing, the use of water flushing or cotton swab wiping to counteract organic interference can effectively kill vaginal Candida. After the ozone water has killed bacteria, it transforms into oxygen, remaining in the vagina to improve the anaerobic environment, which is unfavorable for anaerobic bacteria or fungi growth. Therefore, it can effectively inhibit vaginal reactions, quickly relieve symptoms, and achieve ideal treatment results. In addition to the above, the ozone therapy device also has a definite therapeutic effect on trichomonas, bacterial vaginitis, and vulvitis caused by bacterial infections. Clinical observations have shown that ozone therapy has a therapeutic effect on various vaginal inflammations in women.
Treatment indications: Trichomonas vaginitis, Candida vaginitis, Bacterial vaginitis, Nonspecific vaginitis, Vulvitis, Cervicitis, Pelvic inflammatory disease
Contraindications: Patients with impaired liver or kidney function, Patients with cardiovascular or cerebrovascular diseases, Pregnant and lactating women, Those experiencing genital bleeding, Unknown special populations
Treatment principles: Utilizing ozone water entering the vagina, O3 is released, killing bacteria in the vagina. Simultaneously, it changes the pH value in the vagina, altering the vaginal environment to make it unsuitable for the growth of anaerobic bacteria or fungi. The active oxygen entering the vagina is absorbed by the vaginal mucosal cells, promoting the production and reproduction of immune regulatory cells, thereby accelerating the bactericidal effect.
Treatment characteristics: Efficient and fast: Quickly kills bacteria, and after one treatment, symptoms are significantly alleviated. Especially effective for gynecological diseases that have not been cured for a long time. Non-invasive: Cervical erosion treatment is non-invasive, with a wide treatment area and no dead angles. Safe and non-toxic: The gas acts directly on the affected area, causing no harm to the liver or kidneys. Its reduction product is oxygen, with no toxic side effects. Treatment for both spouses: Males may carry pathogenic microorganisms without symptoms of gynecological diseases. When the female partner is ill, simultaneous use of the instrument by the spouse can prevent cross-infection of gynecological diseases. Treatment time and methods for reference: Treatment should begin 3 days after the end of menstruation. After treating vaginitis, the white discharge should be reexamined after the next menstruation. Candida vaginitis (simple): 5-7 days/treatment, 10 minutes/time/day Candida vaginitis (recurrent): 5-7 days/treatment, 10 minutes/time/day (combined with drug treatment as needed) Bacterial vaginitis, Trichomonas vaginitis, Vulvitis, Cervicitis, etc.: 5-7 days/treatment, 10 minutes/time/day Cervical erosion I degree: 5-7 days/treatment, 10 minutes/time/day, recheck after 10 days Cervical erosion II and III degrees: 10 days/treatment, 10 minutes/time, 2 times/day. Recheck after the next menstruation. Pelvic inflammatory disease: Depending on the condition, administer treatment concurrently with intravenous or oral medication. The time and method depend on the condition.