Email: [email protected] Tel: +86 18626018485


Protable Postpartum Rehabilitation Therapy Device ZJ-2000

Product Name: Postpartum Rehabilitation Therapy DeviceOverview: The Postpartum Rehabilitation Therapy Device is primarily designed for gynecological treatment. After childbirth, the female body undergoes significant physiological and psychological changes. The physical exertion during childbirth, co

          
Product Description:

Product Name: Postpartum Rehabilitation Therapy Device

Overview: The Postpartum Rehabilitation Therapy Device is primarily designed for gynecological treatment. After childbirth, the female body undergoes significant physiological and psychological changes. The physical exertion during childbirth, combined with the anxiety and stress of the pregnancy and delivery periods, can lead to physiological dysfunction in postpartum women, resulting in insufficient milk secretion, slow uterine recovery, and postpartum urinary issues, significantly impacting the recovery of mothers and the care of newborns.

Physiological Effects: Research has demonstrated that low-frequency pulse currents have several physiological effects on the human body, including:

a. Stimulation of nerve and muscle tissues, b. Promotion of local blood circulation, c. Analgesic effects, d. Anti-inflammatory properties.

Treatment Principle: The device utilizes the aforementioned principles by applying specialized skin electrodes to the ienvironment of the human body, thereby facilitating the clearance of mammary ducts, promoting milk secretion, accelerating uterine recovery, and enhancing postpartum urination, achieving clinical therapeutic effects.

Basic Device Parameters:

The device features various modes, including lactation stimulation, insufficient milk secretion, mammary duct clearance, uterine recovery treatment, postpartum urination promotion, and postpartum recovery.

Maximum Output Current: Not exceeding 80mA (under 500-ohm load); Maximum Open Circuit Voltage: Maximum peak-to-peak output ≤300V;

Single Pulse Energy: Maximum output energy not exceeding 300mJ;

The device's output intensity is adjustable in a continuous range from 0 to 250 levels, corresponding to a peak-to-peak output voltage of 0-35V under a 500-ohm load, with an error of ±20%.

The output intensity must start from 0 and be incrementally adjusted for the treatment to be initiated.

Timing: 05-40 minutes with an error of ±10%, in 5-minute increments.

Application Range: Suitable for adjunctive treatment of lactation stimulation, insufficient milk secretion, mammary duct obstruction, postpartum urination promotion, and postpartum recovery.


Get the latest price? We'll respond as soon as possible(within 12 hours)
Leave a message

Facebook

Twitter

LinkedIn

Youtube

instagram

+86 18626018485

Skype

WhatsAPP

[email protected]

8704401

Top